Stackable containers standard format
Stackable containers in STANDARD format are particularly recommended for transport, storage, handling and process operations of all food or other liquids that are not subject to specific restrictive rules. They are, therefore, used for the transport or processing of dairy products, Wine, chocolate, various food creams, hazelnut paste, egg products, cosmetic products, pharmaceuticals and chemicals of various kinds.
stackable containers can be made of stainless steel Aisi 304 or Aisi 316, with load-bearing frame in hot-dip galvanized carbon steel for immersion or in stainless steel Aisi 304, and can be and completed with various accessories.
In addition, our standard stackable containers have capacities ranging from 500 to 1500 liters depending on the model. They can also be thermally insulated with pressure-injected polyurethane foam and equipped with a stainless steel double layer, to allow the maintenance of a controlled temperature Suitable for the product.
![]() |
Standard IBC The PL range of standard IBC is recommended for the handling, storage and transportation of all fluids with NO specific restrictions. Technical features and standard components Optional accessories |
---|
PL 500 | PL 750 | PL 1000 | PL 1250 | PL 1500 | |
A | 980 | 1230 | 1480 | 1730 | 1975 |
B | 500 | 750 | 1000 | 1250 | 1500 |
CAPACITY LT. | 565 | 794 | 1023 | 1251 | 1470 |
WEIGHT Kg* | 120 | 130 | 140 | 155 | 170 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |
![]() |
Standard Insulated IBC The PLI range of standard IBC is recommended for the handling, storage and transportation of all fluids with NO specific restrictions and need to maintain the filling temperature for approximately 24 hours. Technical features and standard components Optional accessories |
---|
PLI 650 | PLI 850 | PLI 1000 | |
A | 1250 | 1500 | 1750 |
B | 750 | 1000 | 1250 |
CAPACITY LT. | 670 | 875 | 1050 |
WEIGHT Kg* | 175 | 200 | 220 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |
![]() |
Standard Insulated IBC with Heating/Cooling Stystem The PLI/R range of standard IBC have been designed for the handling, the storage and the transport of all fluids that during storage should be heated or cooled: this is obtained by circulating in the special jacket a hot or cold liquid. Technical features and standard components Optional accessories |
---|
PLI/R 650 | PLI/R 850 | PLI/R 1000 | |
A | 1250 | 1500 | 1750 |
B | 750 | 1000 | 1250 |
CAPACITY LT. | 670 | 875 | 1050 |
WEIGHT Kg* | 195 | 225 | 255 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |
![]() |
Standard IBC High Density Fluids The PLV range of standard IBC is recommended for the handling, storage and transportation of all fluids with high density and NO specific restrictions. Technical features and standard components Optional accessories |
---|
PLV 600 | PLV 800 | PLV 1000 | PLV 1200 | |
A | 1230 | 1480 | 1730 | 1890 |
B | 500 | 750 | 1000 | 1160 |
CAPACITY LT. | 623 | 852 | 1081 | 1226 |
WEIGHT Kg* | 130 | 140 | 150 | 160 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |

Standard IBC The PL range of standard IBC is recommended for the handling, storage and transportation of all fluids with NO specific restrictions. Technical features and standard components Optional accessories |
---|
PL 500 | PL 750 | PL 1000 | PL 1250 | PL 1500 | |
A | 980 | 1230 | 1480 | 1730 | 1975 |
B | 500 | 750 | 1000 | 1250 | 1500 |
CAPACITY LT. | 565 | 794 | 1023 | 1251 | 1470 |
WEIGHT Kg* | 120 | 130 | 140 | 155 | 170 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |

Standard Insulated IBC The PLI range of standard IBC is recommended for the handling, storage and transportation of all fluids with NO specific restrictions and need to maintain the filling temperature for approximately 24 hours. Technical features and standard components Optional accessories |
---|
PLI 650 | PLI 850 | PLI 1000 | |
A | 1250 | 1500 | 1750 |
B | 750 | 1000 | 1250 |
CAPACITY LT. | 670 | 875 | 1050 |
WEIGHT Kg* | 175 | 200 | 220 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |

Standard Insulated IBC with Heating/Cooling Stystem The PLI/R range of standard IBC have been designed for the handling, the storage and the transport of all fluids that during storage should be heated or cooled: this is obtained by circulating in the special jacket a hot or cold liquid. Technical features and standard components Optional accessories |
---|
PLI/R 650 | PLI/R 850 | PLI/R 1000 | |
A | 1250 | 1500 | 1750 |
B | 750 | 1000 | 1250 |
CAPACITY LT. | 670 | 875 | 1050 |
WEIGHT Kg* | 195 | 225 | 255 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |

Standard IBC High Density Fluids The PLV range of standard IBC is recommended for the handling, storage and transportation of all fluids with high density and NO specific restrictions. Technical features and standard components Optional accessories |
---|
PLV 600 | PLV 800 | PLV 1000 | PLV 1200 | |
A | 1230 | 1480 | 1730 | 1890 |
B | 500 | 750 | 1000 | 1160 |
CAPACITY LT. | 623 | 852 | 1081 | 1226 |
WEIGHT Kg* | 130 | 140 | 150 | 160 |
* Weights are indicative The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer. |
Standard IBC
The PL range of standard IBC is recommended for the handling, storage and transportation of all fluids with NO specific restrictions.
Technical features and standard components
• Stainless steel tank AISI 304 or AISI 316 cold rolled
• Forged bottom with anti-stagnation drain pan
• DN 400 hatch with quick closing – system and specific product contents seal
• Total choice discharge valve 1 ½ “- 2” – 2 ½ “- 3”
• Total choice safety valves single or double action
• Modular cage made of hot galvanized carbon steel
Optional accessories
• Ball or butterfly discharge valves
• Stainless steel modular cage AISI 304
• Screw or handwheel hatch closing systems
• Electric or pneumatic stirrer
• PYREX or PVC visual level
• Cooling/heating systems
• Washing system
PL 500 | PL 750 | PL 1000 | PL 1250 | PL 1500 | |
A | 980 | 1230 | 1480 | 1730 | 1975 |
B | 500 | 750 | 1000 | 1250 | 1500 |
CAPACITY LT. | 565 | 794 | 1023 | 1251 | 1470 |
WEIGHT Kg* | 120 | 130 | 140 | 155 | 170 |
* Weights are indicative
The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer.
Standard Insulated IBC
The PLI range of standard IBC is recommended for the handling, storage and transportation of all fluids with NO specific restrictions and need to maintain the filling temperature for approximately 24 hours.
Technical features and standard components
• Stainless steel tank AISI 304 or AISI 316 cold rolled built in double wall with thermally insulated air cavities with polyurethane foam
• Forged bottom with anti-stagnation drain pan
• DN 400 hatch with quick closing – system and specific product contents seal
• Total choice discharge valve 1 ½ “- 2” – 2 ½ “- 3”
• Total choice safety valves single or double action
• Modular cage made of hot galvanized carbon steel
Optional accessories
• Ball or butterfly discharge valves
• Stainless steel modular cage AISI 304
• Screw or handwheel hatch closing systems
• Electric or pneumatic stirrer
• PYREX or PVC visual level
• Cooling /heating systems
• Washing system
PL 650 | PL 850 | PL 1000 | |
A | 1250 | 1500 | 1750 |
B | 750 | 1000 | 1250 |
CAPACITY LT. | 670 | 875 | 1050 |
WEIGHT Kg* | 175 | 200 | 220 |
* Weights are indicative
The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer.
Standard Insulated IBC with Heating/Cooling Stystem
The PLI/R range of standard IBC have been designed for the handling, the storage and the transport of all fluids that during storage should be heated or cooled: this is obtained by circulating in the special jacket a hot or cold liquid.
Technical features and standard components
• Stainless steel tank AISI 304 or AISI 316 in cold rolled built in double wall thermally insulated with polyurethane foam and a special jacket for the circulation of heating or cooling liquid
• Forged bottom with anti-stagnation drain pan
• DN 400 hatch with quick closing – system and specific product contents seal
• Total choice discharge valve 1 ½ “- 2” – 2 ½ “- 3”
• Total choice safety valves single or double action
• Heating /cooling systems
• Modular cage made of hot galvanized carbon steel
Optional accessories
• Ball or butterfly discharge valves
• Stainless steel modular cage AISI 304
• Screw or handwheel hatch closing systems
• Electric or pneumatic stirrer
• PYREX or PVC visual level
• Cooling/heating systems
• Washing system
PLI/R 650 |
PLI/R 850 |
PLI/R 1000 |
|
A | 1250 | 1500 | 1750 |
B | 750 | 1000 | 1250 |
CAPACITY LT. | 670 | 875 | 1050 |
WEIGHT Kg* | 195 | 225 | 255 |
* Weights are indicative
The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer.
Standard IBC High Density Fluids
The PLV range of standard IBC is recommended for the handling, storage and transportation of all fluids with high density and NO specific restrictions.
Technical features and standard components
• Stainless steel tank AISI 304 or AISI 316 cold rolled
• forged bottom with anti-stagnation drain pan
• DN 400 hatch with quick closing – system and specific product contents seal
• Total choice discharge valve 1 ½ “- 2” – 2 ½ “- 3”
• Total choice safety valves single or double action
• Modular cage made of hot galvanized carbon steel
Optional accessories
• Ball or butterfly discharge valves
• Stainless steel modular cage AISI 304
• Screw or handwheel hatch closing systems
• Electric or pneumatic stirrer
• PYREX or PVC visual level
• Cooling /heating systems
• Washing system
PLV 600 | PLV 800 | PLV 1000 | PLV 1200 | |
A | 1230 | 1480 | 1730 | 1890 |
B | 500 | 750 | 1000 | 1160 |
CAPACITY LT. | 623 | 852 | 1081 | 1226 |
WEIGHT Kg* | 130 | 140 | 150 | 160 |
* Weights are indicative
The information contained in this sheet is subject to change, without notice, at the discretion of the manufacturer.
Standard IBC

PL Range

PLI Range

PLIR Range

PLV Range